3-2
www.moxa.com
Ethernet Media Converters and Extenders
Ethernet Media Converters and Extenders >
3
Product Selection Guide
Chassis Media Converters
TRC-190-AC
TRC-190-DC-48
TRC-2190-AC
TRC-2190-DC-48
TRC-2190-DC-220
CSM-200-1213
CSM-200-1214
CSM-400-1213
CSM-400-1214
CSM-200-1218
CSM-400-1218
Optical Fiber Interface
Fiber Connector
SC or ST SC
Cable Requirements
Multi-mode: 50/125, 62.5/125, or 100/140 μm
Single-mode: 8.3/125,
8.7/125, 9/125, or 10/125 μm
Transmission Distance
5 km 40 km
Wavelength
1300 nm 1310 nm
Tx Output
-10 to -20 dBm 0 to -5 dBm
Rx Sensitivity
-32 dBm -34 dBm
Point-to-Point Transmission
Point-to-Point Transmission: Half-duplex or full-duplex
Point-to-Point Transmission:
Half-duplex or full-duplex
Fast Ethernet Interface
Connector
RJ45
Speed
10/100BaseT(X)
Physical Characteristics
Housing
SECC (1.2 mm)
Dimensions (mm)
440 x 260 x 77 mm 86.8 x 136.5 x 21 mm
Weight
5.2 kg (11.4 lbs), with one power module installed
CSM-200-1213: 115 g (0.25 lb)
CSM-200-1214: 125 g (0.28 lb)
125 g (0.28 lb)
Number of Slots
19 slots in the front for slide-in modules, 2 slots in the back for
power supply modules
Environmental Limits
Operating Temperature
0 to 60°C
Operating Humidity
5 to 95% RH
Storage Temperature
-20 to 75°C
Power Requirements
Input Voltage
AC model: Universal 100 to 240 VAC (47 to 63 Hz)
DC model: 36 to 72 VDC
12 VDC
Power Consumption
3.2 A @ 36 VDC (max. output) 180 mA @ 12 VDC
Standards and Certifications
Safety
UL 60950-1, EN 60950-1
EMC
CE, FCC
EMI
EN 55022 Class A, FCC Part 15 Subpart B Class A
EMS
EN61000-4-2 (ESD) Level 4,
EN61000-4-3 (RS) Level 2,
EN61000-4-4 (EFT) Level 3,
EN61000-4-5 (Surge) Level 3,
EN61000-4-6 (CS) Level 2,
EN61000-4-8 (PFMF) Level 3,
EN61000-4-11 (DIPS)
EN61000-4-2 (ESD) Level 4,
EN61000-4-3 (RS) Level 3,
EN61000-4-4 (EFT) Level 3,
EN61000-4-5 (Surge) Level 3,
EN61000-4-6 (CS) Level 2,
EN61000-4-8 (PFMF) Level 3,
EN61000-4-11 (DIPS)
Freefall
IEC 60068-2-32
Reliability
Warranty
5 years (see www.moxa.com/warranty)