NPort® S8455 Series
Device Connectivity
Serial-to-Ethernet Device Servers >
9
Appearance
Overview
NPort
®
5600 Series
8 and 16-port RS-232/422/485 rackmount serial device servers
With the NPort® 5600 rackmount series, you not only protect your
current hardware investment, but also allow for future network
expansion by centralizing the management of your serial devices and
distributing management hosts over the network.
Network Readiness for up to 16 Serial Devices
Only basic configuration is needed with the NPort® 5600 to connect
up to 16 serial devices to an Ethernet network.
19-inch Rackmount Device Server
NPort® 5600 device servers come with Tx/Rx LEDs for the serial ports
on the front panel, and 8 or 16 RJ45 serial port connectors on the
rear panel. This makes the NPort® 5600 device servers suitable for
standard 19-inch rack mounting, allowing you to simplify operational,
maintenance, and administrative tasks.
Real COM/TTY Ports
Real COM/TTY drivers are provided to make the serial ports on the
NPort® 5600 recognizable as Real COM ports by Windows, or Real
TTY ports by Linux. In addition to supporting basic data transmission
and reception, the NPort® drivers also support the RTS, CTS, DTR,
DSR, and DCD control signals.
LED Indicators to Ease Your Maintenance Tasks
The System LED, serial Tx/Rx LEDs, and Ethernet LEDs (located
on the RJ45 connector) provide a great tool for basic maintenance
tasks and help engineers analyze problems in the field. The LEDs not
only indicate current system and network status, but also help field
engineers monitor the status of attached serial devices.
Adjustable Termination and Pull High/Low Resistors
When using termination resistors to prevent serial signal reflection,
it is important to set the pull high/low resistors correctly so that the
electrical signal is not corrupted. Since no set of resistor values is
universally compatible for all environments, the NPort® 5650-8/16 has
DIP switches on the bottom panel for setting the termination and pull
high/low resistor values.
Mounting plate
AC power input
100 to 240 VAC input, 47 to 63 HZ
LCD
panel
Reset
button
Push
buttons
LED indicators
system status, serial Tx/Rx
Ethernet
RJ45 10/100 Mbps
AC power switch
Connection cable
RJ45 to DB9 cable
(optional accessory)
8 or 16 serial ports supporting RS-232/422/485
Standard 19-inch rackmount size
10/100M auto-sensing Ethernet
Built-in 15 KV ESD protection for all serial signals
Easy IP address conguration with LCD panel (excluding wide
temperature models)
Congure via Telnet/Web/Windows utility
Socket modes: TCP server/TCP client/UDP/Real COM
SNMP MIB-II for network management
Note: LCD panel and configuration buttons not available with wide-temp. models
Serial ports (50 bps to 921.6 Kbps, RJ45 connectors)
NPort® 5610: RS-232
NPort® 5630: RS-422/485
NPort® 5650: RS-232/422/485