1-60
www.moxa.com e-mail: info@moxa.com
1
Selection Guide
Media Converters/Isolators/Repeaters
Model Name
A52
A53
TCC-80
TCC-80I
TCC-82
TCF-90-M
TCF-90-S
TCC-100
TCC-100I
TCC-120
TCC-120I
TCF-142-M
TCF-142-S
Product Category
RS-232 to
RS-422/485
RS-232 to
RS-422/485
RS-232 Isolator
RS-232 to Optical
Fiber
RS-232 to
RS-422/485
RS-422/485
Converter/Re-
peater
RS-232/422/485
toOptical Fiber
– Port powered Port powered Port powered DIN-rail DIN-rail DIN-rail
Interface
RS-232 x 1
RS-422/485 x 1
RS-232 x 1
RS-422/485 x 1
RS-232 x 2
RS-232 x 1
Fiber x 1
RS-232 x 1
RS-422/485 x 1
RS-422/485 x 2
RS-232/422/
485 x 1
Fiber x 1
Connector
RS-232: RJ45
RS-422/485:
RJ45/TB
RS-232: DB9 (F)
RS-422/485: TB
DB9 (F) x 1
DB9 (M) x 1
RS-232: DB9 (F)
Fiber: Optic ST
RS-232: DB9 (F)
RS-422/485: TB
TB
RS232: DB9 (F)
Fiber: Optic ST
Speed
300 bps to
921.6 kbps
300 bps to
115.2 Kbps
300 bps to
115.2 Kbps
300 bps to
115.2 Kbps
300 bps to
921.6 Kbps
300 bps to
230.4 Kbps
300 bps to
921.6 Kbps
Surge ESD Protection 25 KV 15 KV 15 KV 15 KV 15 KV 15 KV 15 KV
Isolation Protection
(for I Model )
2 KV (A53)
2.5 KV
(TCC-80I)
4 KV By Optical Fiber
2 KV
(TCC-100I)
2 KV
(TCC-120I)
Optical fiber
ADDCTM
√
Compatible – –
√ √ √
Power Input 9 to 30 VDC
Port power or
optional
5 to 12 VDC
Port power or
optional
5 to 12 VDC
Port power or
optional
5 to 12 VDC
12 to 48 VDC 12 to 48 VDC 12 to 48 VDC
Operating Temperature
0 to 55˚C
(32 to 131˚F)
0 to 60˚C
(32 to 140˚F)
0 to 60˚C
(32 to 140˚F)
0 to 60˚C
(32 to 140˚F)
-20 to 60˚C
(-4 to 140˚F)
-20 to 60˚C
(-4 to 140˚F)
0 to 60˚C
(32 to 140˚F)
-40 to 75 ˚C
(-40 to 167˚F)
(for T model)
Approval
CE, FCC Class A CE, FCC Class B CE, FCC Class B CE, FCC Class B CE, FCC Class B CE, FCC Class B CE, FCC, TÜV, UL
Warranty 5 years 5 years 5 years 5 years 5 years 5 years 5 years
Media Converters