Moxa EtherDevice™ Switch
EDS-508A/505A Series Users Manual
www.moxa.com/product
Fifth Edition, January 2010
2010 Moxa Inc. All rights reserved.
Reproduction without permission is prohibited.
Przeglądanie stron 0
1 2 3 4 5 6 ... 128 129

Podsumowanie treści

Strona 1 - Moxa EtherDevice™ Switch

Moxa EtherDevice™ Switch EDS-508A/505A Series User’s Manual www.moxa.com/product Fifth Edition, January 2010  2010 Moxa Inc. All right

Strona 2

EDS-508A/505A Series User’s Manual Getting Started 2-33. The Communication Parameter page of the Property window opens. Select the appropriate COM

Strona 3 - Table of Contents

EDS-508A/505A Series User’s Manual Featured Functions 3-85Using Monitor You can monitor statistics in real time from the EDS’s web console and seria

Strona 4

EDS-508A/505A Series User’s Manual Featured Functions 3-86Monitor by Port Access the Monitor by Port function by selecting ALL 10/100M or Port i, in

Strona 5 - Introduction

EDS-508A/505A Series User’s Manual Featured Functions 3-87The table will display the following information: MAC This field shows the MAC address Ty

Strona 6

EDS-508A/505A Series User’s Manual Featured Functions 3-88Using Syslog This function provides the event logs for the syslog server. The function sup

Strona 7 - Features

EDS-508A/505A Series User’s Manual Featured Functions 3-89 NOTE The following events will be recorded into the EDS-508A/505A’s Event Log table, and

Strona 8 - Getting Started

EDS-508A/505A Series User’s Manual Featured Functions 3-903. Select Yes to enter the EDS’s web browser interface and access the web browser interfa

Strona 9

44 Chapter 4 EDS Configurator GUI EDS Configurator is a comprehensive Windows-based GUI that is used to configure and maintain multiple EDS-508A/5

Strona 10

EDS-508A/505A Series User’s Manual EDS Configurator GUI 4-2Starting EDS Configurator To start EDS Configurator, locate and then run the executable f

Strona 11

EDS-508A/505A Series User’s Manual EDS Configurator GUI 4-3Broadcast Search Use the Broadcast Search utility to search the LAN for all EDS switches

Strona 12

EDS-508A/505A Series User’s Manual EDS Configurator GUI 4-4Search by IP address This utility is used to search for EDS switches one at a time. Note

Strona 13

EDS-508A/505A Series User’s Manual Getting Started 2-45. Type 1 to select ansi/VT100 terminal type, and then press Enter. 6. The Console login sc

Strona 14

EDS-508A/505A Series User’s Manual EDS Configurator GUI 4-53. Click the Upgrade Firmware toolbar icon, or select Upgrade under the Firmware menu. I

Strona 15

EDS-508A/505A Series User’s Manual EDS Configurator GUI 4-6Export Configuration The Export Configuration utility is used to save the entire configur

Strona 16 - Featured Functions

EDS-508A/505A Series User’s Manual EDS Configurator GUI 4-7Import Configuration The Import Configuration function is used to import an entire config

Strona 17 -  Using HTTPS/SSL

EDS-508A/505A Series User’s Manual EDS Configurator GUI 4-84. Click Yes in response to the following warning message to accept the new settings. U

Strona 18 - Configuring Basic Settings

EDS-508A/505A Series User’s Manual EDS Configurator GUI 4-93. The status of the switch will now read Unlocked.

Strona 19 - Password

AA Appendix A MIB Groups The EDS-508A/505A comes with built-in SNMP (Simple Network Management Protocol) agent software that supports cold/warm st

Strona 20 - Accessible IP

EDS-508A/505A Series User’s Manual MIB Groups A-2MIB II.10 – Transmission Group dot3 dot3StatsTable MIB II.11 – SNMP Group SnmpBasicG

Strona 21

EDS-508A/505A Series User’s Manual MIB Groups A-3The EDS also provides a private MIB file, located in the file “Moxa-EDS508A-MIB.my” or “Moxa-EDS505

Strona 22

BB Appendix B Modbus/TCP Map EDS-505A Modbus information v1.0 Read Only Registers (Support Function Code 4) 1 Word = 2Bytes Address Data Ty

Strona 23 - Network Parameters

EDS-508A/505A Series User’s Manual Modbus/TCP Map B-20x0055 3 word Ethernet MAC Address Ex: MAC = 00-01-02-03-04-05 Word 0 Hi byte = 0x00 Word

Strona 24

EDS-508A/505A Series User’s Manual Getting Started 2-58. After entering the Main Menu, use the following keys to move the cursor, and to select opt

Strona 25

EDS-508A/505A Series User’s Manual Modbus/TCP Map B-30x1400~0x1413(Port 1)0x1414~0x1427(Port 2)20 word Port 1~5 Description Port Description = &quo

Strona 26 - Daylight Saving Time

EDS-508A/505A Series User’s Manual Modbus/TCP Map B-40x3301 1 word TR 1st Port status 0x0000:Port Disabled 0x0001:Not Redundant 0x0002:Link

Strona 27

EDS-508A/505A Series User’s Manual Modbus/TCP Map B-50x3502 1 word TR2 Coupling Port Backup status (Only using in Dual Homing) 0x0000:Port Disable

Strona 28 - Turbo Ring DIP Switches

EDS-508A/505A Series User’s Manual Modbus/TCP Map B-60x3683 1 word TR2 Ring 2 2nd Port status 0x0000:Port Disabled 0x0001:Not Redundant 0x0002

Strona 29

EDS-508A/505A Series User’s Manual Modbus/TCP Map B-7EDS-508A Modbus information v1.0 Read Only Registers (Support Function Code 4) 1 Word = 2B

Strona 30

EDS-508A/505A Series User’s Manual Modbus/TCP Map B-80x005A 1 word Fault LED Status 0x0000:No 0x0001:Yes 0x0080 1 word DI1 0x0000:Off 0x0001:On

Strona 31

EDS-508A/505A Series User’s Manual Modbus/TCP Map B-90x2100~0x2123 2 word Port 1~8 Rx Packets Ex: port 1 Rx Packets = 0x44332211 Word 0 = 4433 W

Strona 32

EDS-508A/505A Series User’s Manual Modbus/TCP Map B-100x3304 1 word TR Coupling Port status 0x0000:Port Disabled 0x0001:Not Coupling Port 0x00

Strona 33

EDS-508A/505A Series User’s Manual Modbus/TCP Map B-110x3602 1 word TR2 Ring 1 1st Port status 0x0000:Port Disabled 0x0001:Not Redundant 0x000

Strona 34 - Using Port Trunking

EDS-508A/505A Series User’s Manual Modbus/TCP Map B-120x3700 1 word Turbo Chain Switch Role 0x0000:Head 0x0001:Member 0x0002:Tail 0xFFFF: Turbo

Strona 35 - Configuring Port Trunking

EDS-508A/505A Series User’s Manual Getting Started 2-6Perform the following steps to access the console utility by Telnet. 1. Click Start  Run, an

Strona 36

EDS-508A/505A Series User’s Manual Getting Started 2-7Configuration using a Web Browser The EDS’s web browser interface provides a convenient way to

Strona 37 - Configuring SNMP

EDS-508A/505A Series User’s Manual Getting Started 2-8NOTE By default, the EDS’s password is not set (i.e., is blank). You may need to wait a few mo

Strona 38 - SNMP Read/Write Settings

33 Chapter 3 Featured Functions This chapter explains how to access the EDS-508A/505A’s various configuration, monitoring, and administration func

Strona 39 - Trap Settings

EDS-508A/505A Series User’s Manual Featured Functions 3-2 Using Event Log  Using Syslog  Using HTTPS/SSL

Strona 40 - Private MIB information

EDS-508A/505A Series User’s Manual Featured Functions 3-3Configuring Basic Settings The Basic Settings group includes the most commonly used setting

Strona 41

EDS-508A/505A Series User’s Manual Featured Functions 3-4Web Auto-logout (s) Setting Description Factory Default 60 to 86400 (seconds) Disable or

Strona 42

Moxa EtherDevice™ Switch EDS-508A/505A Series User’s Manual The software described in this manual is furnished under a license agreement and may be u

Strona 43 - Segment N+1

EDS-508A/505A Series User’s Manual Featured Functions 3-5Password Setting Description Factory Default Old Password (Max. 16 Characters) Type curre

Strona 44 - Ring Coupling Configuration

EDS-508A/505A Series User’s Manual Featured Functions 3-6 Any host can access the EDS Disable this function by deselecting the Enable the accessib

Strona 45

EDS-508A/505A Series User’s Manual Featured Functions 3-7Description Setting Description Factory Default Media type Displays the media type for e

Strona 46

EDS-508A/505A Series User’s Manual Featured Functions 3-8Network Parameters The Network configuration allows users to configure both IPv4 and IPv6 p

Strona 47 - Configuring “Turbo Ring”

EDS-508A/505A Series User’s Manual Featured Functions 3-9 Global Unicast Address Prefix (Prefix Length: 64 bits) Setting Description Factory Defau

Strona 48 - Configuring “Turbo Ring V2”

EDS-508A/505A Series User’s Manual Featured Functions 3-10Link-Local Address Setting Description Factory Default None The network portion of Link-

Strona 49

EDS-508A/505A Series User’s Manual Featured Functions 3-11NOTE The EDS does not have a real time clock. The user must update the Current Time and Cu

Strona 50

EDS-508A/505A Series User’s Manual Featured Functions 3-12 NOTE Changing the time zone will automatically correct the current time. You should confi

Strona 51 - The Turbo Chain Concept

EDS-508A/505A Series User’s Manual Featured Functions 3-13IEEE 1588 PTP The following information is taken from the NIST website at http://ieee158

Strona 52 - Configuring “Turbo Chain”

EDS-508A/505A Series User’s Manual Featured Functions 3-14Disable the Turbo Ring DIP Switch Setting Description Factory Default Enable the Turbo R

Strona 53

Table of Contents Chapter 1 Introduction ...1-1 Inside t

Strona 54

EDS-508A/505A Series User’s Manual Featured Functions 3-15 “Turbo Ring” DIP Switch Settings DIP 1 DIP 2 DIP 3 DIP 4 ON: Enables this EDS as the R

Strona 55 - The STP/RSTP Concept

EDS-508A/505A Series User’s Manual Featured Functions 3-16NOTE If you use the browser interface to enable the DIP switches (by un-checking the “Disa

Strona 56

EDS-508A/505A Series User’s Manual Featured Functions 3-17System File Update—By Local Import/Export Configuration File To export the configuration

Strona 57 - How STP Works

EDS-508A/505A Series User’s Manual Featured Functions 3-18System File Update—By Backup Media Auto load system configurations when system boots u

Strona 58

EDS-508A/505A Series User’s Manual Featured Functions 3-19Factory Default The Factory Default function is included to give users a quick way of res

Strona 59 - STP Example

EDS-508A/505A Series User’s Manual Featured Functions 3-20When configuring Port Trunking, note that: Each EDS-505A can set a maximum of 2 Port Trunk

Strona 60

EDS-508A/505A Series User’s Manual Featured Functions 3-21Trunk Group (Maximum of 4 trunk groups on EDS-508A and 2 trunk groups on EDS-505A) Setting

Strona 61 - Configuring STP/RSTP

EDS-508A/505A Series User’s Manual Featured Functions 3-22Configuring SNMP The EDS supports SNMP V1/V2c/V3. SNMP V1, and SNMP V2c use a community st

Strona 62

EDS-508A/505A Series User’s Manual Featured Functions 3-23SNMP Read/Write Settings SNMP Versions Setting Description Factory Default V1, V2c, V3,

Strona 63 - Using Traffic Prioritization

EDS-508A/505A Series User’s Manual Featured Functions 3-24User Auth. Type (for SNMP V1, V2c, V3 and V3 only) Setting Description Factory Default N

Strona 64

Configuring Virtual LAN... 3-57 Using Multicast Filtering...

Strona 65

EDS-508A/505A Series User’s Manual Featured Functions 3-251st Trap Server IP/Name Setting Description Factory Default IP or Name Enter the IP addr

Strona 66 - QoS Classification

EDS-508A/505A Series User’s Manual Featured Functions 3-26The Communication Redundancy function allows the user to set up redundant loops in the net

Strona 67 - CoS Mapping

EDS-508A/505A Series User’s Manual Featured Functions 3-27The Turbo Ring and Turbo Ring V2 protocols identify one switch as the master of the networ

Strona 68 - Using Virtual LAN

EDS-508A/505A Series User’s Manual Featured Functions 3-28“Turbo Ring” rings with an even number of EDS units Master If there are 2N EDS units (an e

Strona 69 - Benefits of VLANs

EDS-508A/505A Series User’s Manual Featured Functions 3-29Master For a “Turbo Ring V2” ring, the backup segment is the segment connected to the 2nd

Strona 70 - Communication between VLANs

EDS-508A/505A Series User’s Manual Featured Functions 3-30coupler’s coupling control port with Switch B (for this example). The coupler switch (i.e.

Strona 71

EDS-508A/505A Series User’s Manual Featured Functions 3-31The “dual-ring” option provides another ring coupling configuration, in which two adjacent

Strona 72 - Configuring Virtual LAN

EDS-508A/505A Series User’s Manual Featured Functions 3-32Use the Communication Redundancy page to configure select “Turbo Ring” or “Turbo Ring V2”

Strona 73

EDS-508A/505A Series User’s Manual Featured Functions 3-33Redundancy Protocol Setting Description Factory Default Turbo Ring Select this item to c

Strona 74 - VLAN Table

EDS-508A/505A Series User’s Manual Featured Functions 3-34 NOTE When using the Dual-Ring architecture, users must configure settings for both Ring

Strona 75 - Using Multicast Filtering

11 Chapter 1 Introduction Welcome to the Moxa EtherDevice Switch EDS-508A/505A Series, the Managed Redundant Ethernet Switch designed specially fo

Strona 76 - IGMP Group2

EDS-508A/505A Series User’s Manual Featured Functions 3-35Ring 1/2—2nd Ring Port Status The “Ports Status” indicators show Forwarding for normal t

Strona 77 - IGMP Multicast Filtering

EDS-508A/505A Series User’s Manual Featured Functions 3-36Setting Description Factory Default Enable Select this EDS as Coupler Disable Do not s

Strona 78 - Configuring IGMP Snooping

EDS-508A/505A Series User’s Manual Featured Functions 3-37Moxa’s Turbo Chain is an advanced software-technology that gives network administrators th

Strona 79

EDS-508A/505A Series User’s Manual Featured Functions 3-38Head Switch Configuration Member Switch Configuration Tail Switch Configuration Explan

Strona 80 - Static Multicast MAC

EDS-508A/505A Series User’s Manual Featured Functions 3-39Shows which communication protocol is in use: Turbo Ring, Turbo Ring V2, RSTP, Turbo Chain

Strona 81 - GMRP Table

EDS-508A/505A Series User’s Manual Featured Functions 3-40Setting Description Factory Default Tail Port Select any port of the EDS to be the tail

Strona 82 - Using Port Access Control

EDS-508A/505A Series User’s Manual Featured Functions 3-41STP (802.1D) is a bridge-based system that is used to implement parallel paths for network

Strona 83 - The IEEE 802.1X Concept

EDS-508A/505A Series User’s Manual Featured Functions 3-42What happens if a link failure is detected? As shown in next figure, the STP process recon

Strona 84 - Configuring Static Port Lock

EDS-508A/505A Series User’s Manual Featured Functions 3-43STP Calculation The first step of the STP process is to perform calculations. During this

Strona 85 - Configuring IEEE 802.1X

EDS-508A/505A Series User’s Manual Featured Functions 3-44STP Example The LAN shown in the following figure has three segments, with adjacent segmen

Strona 86 - 802.1X Re-Authentication

EDS-508A/505A Series User’s Manual Introduction 1-2Inside the Future of Industrial Ethernet Technology The trend in industrial communications and au

Strona 87 - Port Access Control Table

EDS-508A/505A Series User’s Manual Featured Functions 3-45Using STP on a Network with Multiple VLANs IEEE Std 802.1D, 1998 Edition, does not take in

Strona 88 - Using Auto Warning

EDS-508A/505A Series User’s Manual Featured Functions 3-46Configuring STP/RSTP The following figures indicate which Spanning Tree Protocol parameter

Strona 89

EDS-508A/505A Series User’s Manual Featured Functions 3-47Forwarding Delay Setting Description Factory DefaultNumerical value input by user The am

Strona 90 - Email Setup

EDS-508A/505A Series User’s Manual Featured Functions 3-48Configuration Limits of RSTP/STP The Spanning Tree Algorithm places limits on three of the

Strona 91 - Event Setup

EDS-508A/505A Series User’s Manual Featured Functions 3-49How Traffic Prioritization Works Traffic prioritization uses the four traffic queues that

Strona 92 - Warning List

EDS-508A/505A Series User’s Manual Featured Functions 3-50Advantages of DiffServ over IEEE 802.1D are:  Configure how you want your switch to trea

Strona 93 - Using Set Device IP

EDS-508A/505A Series User’s Manual Featured Functions 3-51Configuring Traffic Prioritization Quality of Service (QoS) provides a traffic prioritizat

Strona 94 - Configuring Set Device IP

EDS-508A/505A Series User’s Manual Featured Functions 3-52default port priority will take effect. Inspect TOS Setting Description Factory Default

Strona 95 - DHCP Relay Agent (Option 82)

EDS-508A/505A Series User’s Manual Featured Functions 3-535: Medium 6: High 7: High TOS/DiffServ Mapping Setting Description Factory DefaultLow/N

Strona 96 - Using Diagnosis

EDS-508A/505A Series User’s Manual Featured Functions 3-54 Benefits of VLANs The main benefit of VLANs is that they provide a network segmentation

Strona 97

EDS-508A/505A Series User’s Manual Introduction 1-3Package Checklist The Moxa EtherDevice Switch EDS-508A/505A Series is shipped with the following

Strona 98 - LLDP Web Interface

EDS-508A/505A Series User’s Manual Featured Functions 3-55Managing a VLAN A new or initialized EDS contains a single VLAN—the Default VLAN. This VLA

Strona 99 - LLDT Table

EDS-508A/505A Series User’s Manual Featured Functions 3-56The following section illustrates how to use these ports to set up different applications.

Strona 100 - Using Monitor

EDS-508A/505A Series User’s Manual Featured Functions 3-57After proper configuration:  Packets from device A will travel through “Trunk Port 3” wi

Strona 101 - Using the MAC Address Table

EDS-508A/505A Series User’s Manual Featured Functions 3-58VLAN Mode Setting Description Factory Default 802.1Q VLAN Set VLAN mode to 802.1Q VLAN

Strona 102 - Using Event Log

EDS-508A/505A Series User’s Manual Featured Functions 3-59To configure the EDS’s Port-based VLAN, use the VLAN Setting page to configure the ports.

Strona 103 - Using Syslog

EDS-508A/505A Series User’s Manual Featured Functions 3-60NOTE The physical network can have a maximum of 64 VLAN settings. Using Multicast Filterin

Strona 104 - Using HTTPS/SSL

EDS-508A/505A Series User’s Manual Featured Functions 3-61Network without multicast filtering 12345678Serial portsConsole LAN9 10111213141516IGMP Gr

Strona 105

EDS-508A/505A Series User’s Manual Featured Functions 3-62Multicast Filtering and Moxa EtherDevice Switch The EDS has three ways to achieve multicas

Strona 106 - EDS Configurator GUI

EDS-508A/505A Series User’s Manual Featured Functions 3-63GMRP (GARP Multicast Registration Protocol) The EDS supports IEEE 802.1D-1998 GMRP (GARP M

Strona 107 - Starting EDS Configurator

EDS-508A/505A Series User’s Manual Featured Functions 3-64 Learned Multicast Querier Ports  Member Ports Disable IGMP Multicast packets will fo

Strona 108 - Broadcast Search

22 Chapter 2 Getting Started This chapter explains how to access your EDS-508A/505A switch for the first time. There are three ways to access the

Strona 109 - Upgrade Firmware

EDS-508A/505A Series User’s Manual Featured Functions 3-65IGMP Table The EDS displays the current active IGMP groups that were detected. The inform

Strona 110 - Modify IP Address

EDS-508A/505A Series User’s Manual Featured Functions 3-66Configuring GMRP GMRP is a MAC-based multicast management protocol, whereas IGMP is IP-bas

Strona 111 - Export Configuration

EDS-508A/505A Series User’s Manual Featured Functions 3-67Using Bandwidth Management In general, one host should not be allowed to occupy unlimited

Strona 112 - Import Configuration

EDS-508A/505A Series User’s Manual Featured Functions 3-68The IEEE 802.1X Concept Three components are used to create an authentication mechanism ba

Strona 113 - Unlock Server

EDS-508A/505A Series User’s Manual Featured Functions 3-691. When the supplicant receives an “EAP Request/Identity” frame, it sends an “EAP Respons

Strona 114

EDS-508A/505A Series User’s Manual Featured Functions 3-70Configuring IEEE 802.1X Database Option Setting Description Factory DefaultLocal (Max.

Strona 115 - MIB Groups

EDS-508A/505A Series User’s Manual Featured Functions 3-71Re-Auth Setting Description Factory DefaultEnable/Disable Select to require re-authenti

Strona 116

EDS-508A/505A Series User’s Manual Featured Functions 3-72Local User Database Setup When setting the Local User Database as the authentication datab

Strona 117

EDS-508A/505A Series User’s Manual Featured Functions 3-73Using Auto Warning Since industrial Ethernet devices are often located at the endpoints of

Strona 118 - Modbus/TCP Map

EDS-508A/505A Series User’s Manual Featured Functions 3-74 System Events Warning e-mail is sent when… Switch Cold Start Power is cut off and then

Strona 119

EDS-508A/505A Series User’s Manual Getting Started 2-2RS-232 Console Configuration (115200, None, 8, 1, VT100) NOTE Connection Caution! 1. You cann

Strona 120

EDS-508A/505A Series User’s Manual Featured Functions 3-75Email Setup Mail Server IP/Name Setting Description Factory DefaultIP address The IP A

Strona 121

EDS-508A/505A Series User’s Manual Featured Functions 3-76NOTE Auto warning e-mail messages will be sent through an authentication protected SMTP se

Strona 122

EDS-508A/505A Series User’s Manual Featured Functions 3-77 System Events Warning Relay output is triggered when… Power Transition (OnOff) The EDS

Strona 123

EDS-508A/505A Series User’s Manual Featured Functions 3-78Using Line-Swap-Fast-Recovery The Line-Swap Fast Recovery function, which is enabled by de

Strona 124

EDS-508A/505A Series User’s Manual Featured Functions 3-79STEP 1—set up the connected devices Set up those Ethernet-enabled devices connected to the

Strona 125

EDS-508A/505A Series User’s Manual Featured Functions 3-80Desired IP Address Setting Description Factory DefaultIP Address Set the desired IP of

Strona 126

EDS-508A/505A Series User’s Manual Featured Functions 3-81 Using Diagnosis The EDS provides two important tools for administrators to diagnose netwo

Strona 127

EDS-508A/505A Series User’s Manual Featured Functions 3-82Perform the following steps to set up the Mirror Port function: STEP 1 Configure the EDS’s

Strona 128

EDS-508A/505A Series User’s Manual Featured Functions 3-83LLDP Function Overview Defined by IEEE 802.11AB, LLDP is an OSI Layer 2 Protocol that stan

Strona 129

EDS-508A/505A Series User’s Manual Featured Functions 3-84LLDP Settings Enable LLDP Setting Description Factory DefaultEnable or Disable Enable o