Moxa Technologies NPort Server Pro Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Serwery Moxa Technologies NPort Server Pro. Moxa Technologies NPort Server Pro User`s manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - MOXA Technologies Co., Ltd

CN2510 Async Server User’s Manual Third Edition, June 2006 www.moxa.com/product MOXA Technologies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1

Strona 2 - Disclaimer

CN2510 User’s Manual Introduction 1-3Front Panel RxTx12345678ResetReadySELMENUCN25108 port RS-232 Async ServerLCM Display PanelReset Button Ready LE

Strona 3 - Table of Contents

CN2510 User’s Manual Setting Up Raw UDP 6-2 Accessing the Console Utility NOTE In this section, we show how to access CN2510’s console utility by Te

Strona 4

CN2510 User’s Manual Setting Up Raw UDP 6-3Selecting the Application Open Port Menu Æ Mode to configure the Raw UDP application. 1. From the MAIN M

Strona 5

CN2510 User’s Manual Setting Up Raw UDP 6-45. The only operation mode associated with this application is RAW UDP, which is selected automatically

Strona 6

CN2510 User’s Manual Setting Up Raw UDP 6-5Setting Value Notes NecessityDest. IP address 1/2/3/4 Begin: x.x.x.x End: y.y.y.y Port: 1 to 65535 Def

Strona 7

CN2510 User’s Manual Setting Up Raw UDP 6-6Configuring the Serial Ports Open Port Menu Æ Line to configure serial port settings. 1. From the MAIN M

Strona 8 - Introduction

CN2510 User’s Manual Setting Up Raw UDP 6-7Save When exiting the SERVER MENU, you will be prompted to save settings. Press Y to save. CN2510-8

Strona 9 - Package Checklist

CN2510 User’s Manual Setting Up Raw UDP 6-82. Select System and then press Enter to restart the system and terminate the Telnet session. CN2510-8

Strona 10 - Bottom Label

77 Chapter 7 Setting Up Reverse Terminal In this chapter, we show how to use CN2510 to connect terminals to a computer over an Ethernet network. T

Strona 11 - Getting Started

CN2510 User’s Manual Setting Up Reverse Terminal 7-2Accessing the Console Utility NOTE In this section, we show how to access CN2510’s console utili

Strona 12 - Hardware Installation

CN2510 User’s Manual Setting Up Reverse Terminal 7-3Selecting the Application Open Port Menu Æ Mode to configure the Reverse Terminal application. 1

Strona 13 - Wiring Requirements

22 Chapter 2 Getting Started This chapter includes instructions on where and how to install CN2510 Async Server. Both basic and advanced software

Strona 14 - Connecting to the Network

CN2510 User’s Manual Setting Up Reverse Terminal 7-45. The only operation mode associated with this application is Reverse Terminal mode, which is

Strona 15 - Configuration Checklist

CN2510 User’s Manual Setting Up Reverse Terminal 7-5Setting Value Notes NecessityTCP port number Each of CN2510’s serial ports is mapped to a T

Strona 16 - Using Telnet

CN2510 User’s Manual Setting Up Reverse Terminal 7-62. From the PORT MENU, select Line, and then press Enter. CN2510-8 CN25

Strona 17

CN2510 User’s Manual Setting Up Reverse Terminal 7-7Save When exiting the SERVER MENU, you will be prompted to save settings. Press Y to save. CN251

Strona 18

88 Chapter 8 Setting Up Terminal In this chapter, we describe the steps you should follow to configure Moxa CN2510 as a Terminal Server. CN2510 pr

Strona 19

CN2510 User’s Manual Setting Up Terminal 8-2 Accessing the Console Utility NOTE In this section, we show how to access CN2510’s console utility by T

Strona 20 - 7. Click on Close

CN2510 User’s Manual Setting Up Terminal 8-3Selecting the Application Open Port Menu Æ Mode to configure the Terminal application. 1. From the MAIN

Strona 21

CN2510 User’s Manual Setting Up Terminal 8-45. TERM_ASC mode is selected by default. CN2510-8 CN2510-8_5631 V2.0

Strona 22

CN2510 User’s Manual Setting Up Terminal 8-53. Move the cursor to the Description/more setting column and press Enter. CN2510-8

Strona 23 - Server Configuration—Info

CN2510 User’s Manual Setting Up Terminal 8-6Setting Value Notes Necessity Telnet TCP port 23 By default, the Telnet TCP port number is set to 2

Strona 24 - Server Configuration—LAN

CN2510 User’s Manual Getting Started 2-2Hardware Installation Desktop Place your CN2510 on a clean, flat, well-ventilated desktop. For better ventil

Strona 25 - Server Configuration—Adv

CN2510 User’s Manual Setting Up Terminal 8-7Configuring TERM_BIN Mode TERM_BIN (Terminal Binary) mode is used as an application protocol. For exampl

Strona 26

CN2510 User’s Manual Setting Up Terminal 8-84. The pop-up selector contains input/display fields for Quit key, Auto-link protocol, Link by input IP

Strona 27

CN2510 User’s Manual Setting Up Terminal 8-9Setting Value Notes Necessity Login user name Login ID Optional Login password Login Password

Strona 28

CN2510 User’s Manual Setting Up Terminal 8-103. The Line page has pop-up selection lists for Port, Speed, Bits, Stop, Parity, FIFO, RTS/CTS, XON/XO

Strona 29

CN2510 User’s Manual Setting Up Terminal 8-11You may also save all settings from the MAIN MENU by selecting sAve and then pressing Enter. Press Ente

Strona 30

99 Chapter 9 Setting Up Multi-host TTY The Multi-host TTY application is the ideal transmission method for communicating with multiple Unix hosts

Strona 31 - Knowing Your Application

CN2510 User’s Manual Setting Up Multi-Host TTY 9-2 Accessing the Console Utility NOTE In this section, we show how to access CN2510’s console utilit

Strona 32 - Console LAN

CN2510 User’s Manual Setting Up Multi-Host TTY 9-3Selecting the Application Open Port Menu Æ Mode to configure the Multi-host TTY application. 1. F

Strona 33 - Linux, Unix

CN2510 User’s Manual Setting Up Multi-Host TTY 9-45. The only operation mode associated with this application is FIXTTY mode, which is selected aut

Strona 34

CN2510 User’s Manual Setting Up Multi-Host TTY 9-5Setting Value Notes NecessityMax. Sessions 1-8 Select the maximum number of simultaneous sess

Strona 35 - UDP datagram

CN2510 User’s Manual Getting Started 2-3Wiring Requirements ATTENTION Safety First! Be sure to disconnect the power cord before installing and/or w

Strona 36

CN2510 User’s Manual Setting Up Multi-Host TTY 9-63. The Line page has pop-up selection lists for Port, Speed, Bits, Stop, Parity, FIFO, RTS/CTS, X

Strona 37 - Terminal Access (Terminal)

CN2510 User’s Manual Setting Up Multi-Host TTY 9-7You may also save all settings from the MAIN MENU by selecting sAve and then pressing Enter. Press

Strona 38

CN2510 User’s Manual Setting Up Multi-Host TTY 9-84. Compile and link documents: SCO OpenServer : # make sco SCO UnixWare : # make svr5 Unix

Strona 39

CN2510 User’s Manual Setting Up Multi-Host TTY 9-9Transparent Printer Access It’s not necessary to add additional entries to /etc/inittab for printe

Strona 40

1100 Chapter 10 Setting Up Dialin/out In this chapter, we describe the steps required to configure Moxa CN2510 as a Dial-in/out Access Server. Dia

Strona 41

CN2510 User’s Manual Setting Up Dial-in/Out 10-2 Accessing the Console Utility NOTE In this section, we show how to access CN2510’s console utility

Strona 42 - Real TTY/Unix Fixed TTY

CN2510 User’s Manual Setting Up Dial-in/Out 10-3Selecting the Application Open Port Menu Æ Mode to configure the Dial-up/out application. 1. From t

Strona 43

CN2510 User’s Manual Setting Up Dial-in/Out 10-45. The Dialin/out application supports five operation modes: DYNAMIC, PPP, PPPD, SLIP, SLIPD. DYNAM

Strona 44

CN2510 User’s Manual Setting Up Dial-in/Out 10-53. Move the cursor to the Description/more setting column, and then press Enter. CN2510-8

Strona 45 - Configuring ASPP Mode

CN2510 User’s Manual Setting Up Dial-in/Out 10-6Setting Value Notes NecessityIncoming PAP check None/local/server None: Authentication is not r

Strona 46

CN2510 User’s Manual Getting Started 2-4NOTE Use 8 kg-cm of screw torque and 22-14 AWG electric wire to connect CN2510-8/16-48V’s power cord to its

Strona 47

CN2510 User’s Manual Setting Up Dial-in/Out 10-73. Move the cursor to the Description/more setting column, and then press Enter. CN2510-8

Strona 48

CN2510 User’s Manual Setting Up Dial-in/Out 10-8Setting Value Notes NecessityIncoming PAP check None/local/server None: Authentication is not r

Strona 49

CN2510 User’s Manual Setting Up Dial-in/Out 10-93. Move the cursor to the Description/more setting column, and then press Enter. CN2510-8

Strona 50

CN2510 User’s Manual Setting Up Dial-in/Out 10-106. The pop-up selector contains input/display fields for Quit key, Auto-link protocol, Link by inp

Strona 51

CN2510 User’s Manual Setting Up Dial-in/Out 10-11Setting Value Notes Necessity Password prompt assword: Send Password information when this pro

Strona 52

CN2510 User’s Manual Setting Up Dial-in/Out 10-12Setting Value Notes NecessitySource IP address IP address for the port CN2510 will automatically

Strona 53

CN2510 User’s Manual Setting Up Dial-in/Out 10-13Setting Value Notes NecessityTCP/IP compression Yes/No Depends on whether the remote user’s app

Strona 54

CN2510 User’s Manual Setting Up Dial-in/Out 10-14Setting Value Notes RTS/CTS Yes, No Hardware Flow Control XON/XOFF Yes, No Software Flow Cont

Strona 55

CN2510 User’s Manual Setting Up Dial-in/Out 10-15Setting Value Notes Enable yes/no Enable modem settings Initialize String Set the modem initi

Strona 56 - Installing Ports

CN2510 User’s Manual Setting Up Dial-in/Out 10-162. From the SERVER MENU, select User_table, and then press Enter. CN2510-8

Strona 57

CN2510 User’s Manual Getting Started 2-5NOTE If your network is already set up, telnet over the network to CN2510’s IP address to access the Console

Strona 58

CN2510 User’s Manual Setting Up Dial-in/Out 10-17Restart 1. From the MAIN MENU, select Restart. CN2510-8 CN2510-8_5631 V2.0

Strona 59

1111 Chapter 11 Setting Up Printer In this chapter, we describe how to set up Moxa CN2510 as a printer server. Up to 16 serial printers can be con

Strona 60

CN2510 User’s Manual Setting Up Printer 11-2Accessing the Console Utility NOTE In this section, we show how to access CN2510’s console utility by Te

Strona 61

CN2510 User’s Manual Setting Up Printer 11-3Selecting the Application Open Port Menu Æ Mode to set up the Printer application. 1. From the MAIN MEN

Strona 62

CN2510 User’s Manual Setting Up Printer 11-45. The Dialin/out application supports two operation modes: RAW PRN and LPD PRN. RAW PRN mode is select

Strona 63 - Configuration page

CN2510 User’s Manual Setting Up Printer 11-53. Move the cursor to the Description/more setting column, and then press Enter. CN2510-8

Strona 64 - Setting

CN2510 User’s Manual Setting Up Printer 11-6Configuring LPD PRN Mode 1. Move the cursor to the Mode column for the port and then press Enter. CN251

Strona 65 - Installing a Server

CN2510 User’s Manual Setting Up Printer 11-7Setting Value Notes NecessityQueue name (RAW) Text Specify print queue’s name (in RAW mode) Fixed

Strona 66

CN2510 User’s Manual Setting Up Printer 11-8Setting Value Notes Speed 50 bps to 921.6 Kbps Transmission rate Bits 5, 6, 7, 8 Data bits Stop 1

Strona 67

CN2510 User’s Manual Setting Up Printer 11-9Restart 1. From the MAIN MENU, select Restart. CN2510-8 CN2510-8_5631 V2.0

Strona 68

CN2510 User’s Manual Getting Started 2-63. The CN2510 Utility lists all available servers on the network. Note that servers in grey are password pr

Strona 69

CN2510 User’s Manual Setting Up Printer 11-10Setting up Unix Hosts UNIX uses the RLP program for remote parallel printing. For serial printing, Moxa

Strona 70

CN2510 User’s Manual Setting Up Printer 11-11Setting up a SOLARIS X86 Host Steps SCO UNIX Command Description Set free the occupied Floppy disk #/e

Strona 71

CN2510 User’s Manual Setting Up Printer 11-12Setting up a LINUX Host Steps SCO UNIX Command Description Uncompress all programs #tar /dev/fd0 ./

Strona 72

CN2510 User’s Manual Setting Up Printer 11-13Setting up Windows Hosts Windows uses the LPD/LPR application to access printers. Moxa provides LPD PRN

Strona 73

CN2510 User’s Manual Setting Up Printer 11-145. After the Microsoft TCP/IP Printing service is added, reboot your computer. 6. At this point, you

Strona 74

CN2510 User’s Manual Setting Up Printer 11-1510. In the window that opens next, click on Add Port. 11. Select LPR Port. Click on New Port…. 12.

Strona 75

CN2510 User’s Manual Setting Up Printer 11-1614. Select the printer’s manufacturer and model name. Click on Next to continue. 15. Enter the pri

Strona 76

CN2510 User’s Manual Setting Up Printer 11-17Setting up a Windows 2000 Host 1. Click on Start Æ Settings Æ Printers. 2. Click on Add Printer to s

Strona 77

CN2510 User’s Manual Setting Up Printer 11-184. Select Local printer, and click on Next to continue. 5. Select Create a new port:, and then sel

Strona 78

CN2510 User’s Manual Setting Up Printer 11-197. Select the printer’s manufacturer and model name. Click on Next to continue. 8. Enter the printer

Strona 79

CN2510 User’s Manual Getting Started 2-73. CN2510’s MAIN MENU will open, as shown below. Telnet 192.168.127.254 CN2510-8 C

Strona 80

CN2510 User’s Manual Setting Up Printer 11-209. Select Shared when prompted with questions asking if the printer is to be shared or not, and then e

Strona 81

CN2510 User’s Manual Setting Up Printer 11-2111. If you want to print a test page, reboot Windows 2000, select this printer, and click on Print Tes

Strona 82

1122 Chapter 12 Setting Up Multiplex In this chapter, we describe how to configure Moxa CN2510 as a Multiplexor and De-Multiplexor. Using the Mult

Strona 83

CN2510 User’s Manual Setting Up Multiplexor 12-2 Accessing the Console Utility NOTE In this section, we show how to access CN2510’s console utility

Strona 84

CN2510 User’s Manual Setting Up Multiplexor 12-3Selecting the Application The Multiplex application uses two Async Servers. One of the servers (call

Strona 85

CN2510 User’s Manual Setting Up Multiplexor 12-42. From the PORT MENU, select Mode, and then press Enter. CN2510-8 CN2510-8

Strona 86

CN2510 User’s Manual Setting Up Multiplexor 12-55. The Multiplex application supports two operation modes: RTELNET and TERM_BIN. RTELNET mode is se

Strona 87

CN2510 User’s Manual Setting Up Multiplexor 12-6Setting Value Notes NecessityTCP port number Each of CN2510’s serial ports is mapped to a TCP p

Strona 88 - Setting Up Device Control

CN2510 User’s Manual Setting Up Multiplexor 12-7Configuring the “Device” CN2510 1. From the MAIN MENU, select Port, and then press Enter. CN2510-8

Strona 89

CN2510 User’s Manual Setting Up Multiplexor 12-85. The Multiplex application supports two operation modes: RTELNET and TERM_BIN. RTELNET mode is se

Strona 90

CN2510 User’s Manual Getting Started 2-82. Click on Next to Continue. 3. Select the I Agree option and then click on Next.

Strona 91

CN2510 User’s Manual Setting Up Multiplexor 12-98. The next step is to configure the TERM_BIN parameters. CN2510-8 CN2510-8

Strona 92

CN2510 User’s Manual Setting Up Multiplexor 12-10Setting Value Notes Necessity Quit Key ^E Defines the Quit key used to disconnect the link bet

Strona 93 - Configuring RAW Mode

CN2510 User’s Manual Setting Up Multiplexor 12-11Setting Value Notes Necessity TCP alive check time 0-99 minutes The time period CN2510 waits bef

Strona 94

CN2510 User’s Manual Setting Up Multiplexor 12-123. The Line page has pop-up selection lists for Port, Speed, Bits, Stop, Parity, FIFO, RTS/CTS, XO

Strona 95

CN2510 User’s Manual Setting Up Multiplexor 12-13You may also save all settings from the MAIN MENU by selecting sAve and then pressing Enter. Press

Strona 96

1133 Chapter 13 Setting Up Routing Routing is the main process used by Internet hosts to deliver packets. The Internet uses a hop-by-hop routing m

Strona 97 - ASPP Examples for Unix

CN2510 User’s Manual Setting Up Routing 13-2Accessing the Console Utility NOTE In this section, we show how to access CN2510’s console utility by Te

Strona 98 - ASPP Examples for Windows

CN2510 User’s Manual Setting Up Routing 13-3What is RIP? RIP (Routing Information Protocol) is a protocol used widely to manage routing information

Strona 99 - Setting Up Raw UDP

CN2510 User’s Manual Setting Up Routing 13-43. Use the Up/Down arrow keys to move the cursor to the Routing protocol pop-up selector. Press Enter t

Strona 100

CN2510 User’s Manual Setting Up Routing 13-53. Use the tab and arrow keys to move the cursor to configure Gateway, Destination, Netmask, and Metric

Strona 101 - Selecting the Application

CN2510 User’s Manual Getting Started 2-94. Select a directory in which to install the CN2510 Utility, and then click on Next. 5. Click on Next to

Strona 102 - Configuring RAW UDP Mode

CN2510 User’s Manual Setting Up Routing 13-6For this example, the Notebook PC dials in to the CN2510 to request a connection to Internet host 210.48

Strona 103

CN2510 User’s Manual Setting Up Routing 13-7Configuring Multiple-Point Routes CN2510Console ServerCN2510Console ServerCN2510Console ServerTCP/IPEthe

Strona 104 - Configuring the Serial Ports

CN2510 User’s Manual Setting Up Routing 13-8Save When exiting the SERVER MENU, you will be prompted to save settings. Press Y to save. CN2510-8

Strona 105 - Restart

1144 Chapter 14 Administrative Utilities In this chapter, we show how to use CN2510 administrative utilities, which include Ping (to see if a LAN

Strona 106

CN2510 User’s Manual Administrative Utilities 14-2Ping Ping is used to test network hardware connectivity and whether a network host is active. 1.

Strona 107 - Setting Up Reverse Terminal

CN2510 User’s Manual Administrative Utilities 14-33. Each item is discussed in the following subsections. CN2510-8 CN2510-

Strona 108

CN2510 User’s Manual Administrative Utilities 14-4Network 1. From the MONITOR MENU, select Network, and then press Enter. CN2510-8

Strona 109

CN2510 User’s Manual Administrative Utilities 14-5UDP statistics Received: Received UDP datagram packets. ErrPorts: Received UDP datagram packet

Strona 110 - Configuring RTELNET Mode

CN2510 User’s Manual Administrative Utilities 14-6Routing 1. From the MONITOR MENU, select Routing, and then press Enter. CN2510-8

Strona 111

CN2510 User’s Manual Administrative Utilities 14-72. Use the arrow keys to select the port you wish to trace, and then press Enter to select. CN251

Strona 112

CN2510 Async Server User’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance wit

Strona 113

CN2510 User’s Manual Getting Started 2-106. Wait while the PComm Lite software is installed. 7. Click on Close.

Strona 114 - Setting Up Terminal

CN2510 User’s Manual Administrative Utilities 14-82. If any of these tests fails, contact Moxa to request repair services. CN2510-8

Strona 115

CN2510 User’s Manual Administrative Utilities 14-93. Specify the new firmware file used to upgrade. Click on OK to start. 4. When the Download ok

Strona 116

CN2510 User’s Manual Administrative Utilities 14-102. Use an RJ45-DB9 female cable to connect to the console port, and then turn on CN2510. Start t

Strona 117 - Configuring TERM_ASC Mode

CN2510 User’s Manual Administrative Utilities 14-115. Type 1 to choose ansi/VT100 terminal type, and then press Enter to enter the MAIN MENU. 6.

Strona 118

CN2510 User’s Manual Administrative Utilities 14-123. Select Console port (using XMODEM) for Upgrade type, and then press Ctrl-U to start. 4. Whe

Strona 119

CN2510 User’s Manual Administrative Utilities 14-135. Select Port Manager Æ File Transfer from the menu bar. 6. In the File Transfer window selec

Strona 120 - Configuring TERM_BIN Mode

CN2510 User’s Manual Administrative Utilities 14-147. Locate the upgrade file, CN2510_2.ROM for example, and then click on Open to transfer the fir

Strona 121

CN2510 User’s Manual Administrative Utilities 14-15NOTE The file must contain at least a host, and if the login ID is different on the remote host,

Strona 122

CN2510 User’s Manual Administrative Utilities 14-16Export Settings can be exported to a file to backup the configuration, or to set up another CN251

Strona 123

CN2510 User’s Manual Administrative Utilities 14-174. Select Console port (using XMODEM) for upgrade type, and then press Ctrl-U to start. 5. Whe

Strona 124

CN2510 User’s Manual Getting Started 2-118. When the installation is complete, select Start Æ Programs Æ PComm Terminal Emulator to run PComm Termi

Strona 125 - Setting Up Multi-host TTY

CN2510 User’s Manual Administrative Utilities 14-186. Select Port Manager Æ File Transfer from the menu. 7. In the File Transfer window select XM

Strona 126

CN2510 User’s Manual Administrative Utilities 14-19Remote RCP Export As we pointed out earlier, RCP is a file transfer protocol that does not requir

Strona 127

CN2510 User’s Manual Administrative Utilities 14-203. From the SETTING MENU, select Import, and then press Enter. 4. Select Console port (using

Strona 128 - Configuring FIXTTY Mode

CN2510 User’s Manual Administrative Utilities 14-216. Select Port Manager Æ File Transfer from the menu. 7. In the File Transfer window select XM

Strona 129

CN2510 User’s Manual Administrative Utilities 14-22Remote RCP Import As we pointed out earlier, RCP is a file transfer protocol that does not requir

Strona 130

CN2510 User’s Manual Administrative Utilities 14-233. Press Enter to confirm that you wish to erase all settings and restore the default settings.

Strona 131 - Setting up Hosts

AA Appendix A Troubleshooting In this appendix, we give solutions to various problems you may come across when using CN2510. The following topics

Strona 132 - Terminal Access

CN2510 User’s Manual Troubleshooting A-2Console Terminal Problems Problem: No message is displayed on the console terminal. Solutions: ¾ Check to s

Strona 133 - Using Fixed TTY Driver

CN2510 User’s Manual Troubleshooting A-3Question: If I forget the password for my CN2510, what should I do? Solution: ¾ Press the Reset button on t

Strona 134 - Setting Up Dialin/out

CN2510 User’s Manual Troubleshooting A-4Question: My application involves connecting the console port of a CISCO router/switch to a Moxa Async Serve

Strona 135

CN2510 User’s Manual Getting Started 2-1211. Click on the Terminal tab and select VT100 for terminal type. Press Enter to confirm. 12. Type 1 to

Strona 136

CN2510 User’s Manual Troubleshooting A-5How to Save CN2510’s Parameters Question: How can I save CN2510’s parameters to recover from unexpected powe

Strona 137 - Configuring PPPD/PPP Mode

CN2510 User’s Manual Troubleshooting A-6SLIP/PPP Connection Problems Problem: Cannot make a SLIP connection to a remote host. Solutions: ¾ Check to

Strona 138

BB Appendix B RADIUS Server Managing dispersed serial lines and modem pools for large numbers of users can create the need for significant adminis

Strona 139 - Configuring SLIPD/SLIP Mode

CN2510 User’s Manual RADIUS Server B-2What is RADIUS? Definition Remote Authentication Dial-up User Service, or RADIUS, is the standard for centrali

Strona 140

CN2510 User’s Manual RADIUS Server B-32. From the SERVER MENU, select Adv., and then press Enter. CN2510-8 CN2510-8_5631

Strona 141 - Configuring Dynamic Mode

CN2510 User’s Manual RADIUS Server B-4+------------------------------------------------+| Enable Detail-setting || TERM_BIN mode [yes] [Term

Strona 142

CN2510 User’s Manual RADIUS Server B-5+------------------------------------------------+| Key Mapping : || Max. Sessions : [ 8 ] ||

Strona 143

CN2510 User’s Manual RADIUS Server B-6Setting up Windows NT Hosts Install Windows NT OPTION PACK 4.0 to Windows NT server. 1. Start Æ Programs Æ Wi

Strona 144

CN2510 User’s Manual RADIUS Server B-74. Right click on RADIUS in the left info window, and then select Properties. 5. Select Service. Check the

Strona 145

CN2510 User’s Manual RADIUS Server B-8Setting up Windows 2000 Hosts 1. Click on Start Æ Programs Æ Administrative Tools Æ Routing and Remote Access

Strona 146

CN2510 User’s Manual Getting Started 2-13Configuring CN2510—The Server Menu In this section, we describe both basic and advanced configuration tasks

Strona 147

CN2510 User’s Manual RADIUS Server B-95. Select TCP/IP protocol, and then click on Next to continue. 6. Specify an IP address.

Strona 148 - Optional Welcome Message

CN2510 User’s Manual RADIUS Server B-10 7. Select Yes, I want to use a RADIUS server, and then click on Next to start using this function.

Strona 149

CN2510 User’s Manual RADIUS Server B-11Setting up Windows 2003 Hosts Windows 2003 uses IAS service instead of RADIUS service. For this reason, you n

Strona 150

CN2510 User’s Manual RADIUS Server B-124. After the installation is finished, click on Administrative Tools, and run Internet Authentication Servic

Strona 151 - Setting Up Printer

CC Appendix C SNMP Agent with MIB II Simple Network Management Protocol agent software is built into CN2510. The software supports cold/warm start

Strona 152

CN2510 User’s Manual SNMP Agent with MIB II C-2 UDP MIB TCP MIB SNMP MIB UdpInDatagrams tcpRtoAlgorithm snmpInPkts UdpNoPorts tcpRtoMin snmpOutP

Strona 153

DD Appendix D Pin Assignments and Cable Wiring In this appendix, common pin assignment and cable wiring diagrams are presented. The following topi

Strona 154 - Configuring RAW PRN Mode

CN2510 User’s Manual Pin Assignments and Cable Wiring D-2Pin Assignments 10/100BaseTX Port Pin Assignment Pin Signal 1 Tx+ 2 Tx- 3 Rx+

Strona 155

CN2510 User’s Manual Pin Assignments and Cable Wiring D-3Async RS-232 Port Cable Wiring 8-pin RJ45 to Male DB9 for CN2510 CN2510DSRRTSGNDTxDRxDDCDCT

Strona 156 - Configuring LPD PRN Mode

CN2510 User’s Manual Pin Assignments and Cable Wiring D-48-pin RJ45 to Male DB25 for CN2510 CN2510DSRRTSGNDTxDRxDDCDCTSDTRRS-232DeviceDTRCTSGNDRxDTx

Strona 157

CN2510 User’s Manual Getting Started 2-14Domain Name Server in the Domain server 1 IP address field, and the IP address of the secondary Domain Name

Strona 158

EE Appendix E LCM Display For first time installation, we recommend using the LCM display and four push buttons to configure the IP address. Basic

Strona 159

CN2510 User’s Manual LCM Display E-2C N 2 5 1 0 - 0 8 _ 0 3 1 9 2 . 1 6 8 . 1 2 7 . 2 5 4 MENU M a i n M e n U S e r v e

Strona 160 - Setting up Unix Hosts

CN2510 User’s Manual LCM Display E-3The first type involves entering numbers, such as IP addresses, Netmasks, etc. In this case, you change the numb

Strona 161

FF Appendix F Service Information In this appendix, we show you how to contact Moxa for information about this and other products, and how to repo

Strona 162 - Setting up a LINUX Host

CN2510 User’s Manual Service Information F-2MOXA Internet Services Customer satisfaction is our number one concern, and to ensure that customers rec

Strona 163 - Setting up Windows Hosts

CN2510 User’s Manual Service Information F-3Problem Report Form MOXA CN2510 Series Customer name: Company: Tel: Fax: Email: Date: 1. Moxa Produc

Strona 164

CN2510 User’s Manual Service Information F-4Product Return Procedure For product repair, exchange, or refund, the customer must:  Provide evidenc

Strona 165

CN2510 User’s Manual Getting Started 2-15DHCP (client)—When DHCP is enabled, CN2510 will request an available IP address and Netmask over the networ

Strona 166

CN2510 User’s Manual Getting Started 2-163. The Adv. page contains input/display fields for RADIUS server IP, RADIUS key, UDP port, Enable RADIUS a

Strona 167

CN2510 User’s Manual Getting Started 2-17Routing protocol—CN2510 supports RIP (Routing Information Protocol) versions 1 and 2, a widely used protoco

Strona 168

CN2510 User’s Manual Getting Started 2-182. From the SERVER MENU, select Route_table, and then press Enter. CN2510-8 CN2510

Strona 169 - Click on Next to continue

CN2510 User’s Manual Getting Started 2-193. The User_table is used for local authentication for dial-in/out access. The CN2510 User Table, which ho

Strona 170

Table of Contents Chapter 1 Introduction...1-1 Product Fe

Strona 171 - Test Page

CN2510 User’s Manual Getting Started 2-20Restart 1. From the MAIN MENU, select Restart. CN2510-8 CN2510-8_5631 V2.0

Strona 172 - Setting Up Multiplex

33 Chapter 3 Knowing Your Application This chapter discusses a variety of applications for CN2510 Async Server. Refer to the diagrams in each sect

Strona 173

CN2510 User’s Manual Knowing Your Application 3-2Windows Real COM (NT Real COM) POSTerminalBar CodeReaderPOSTerminalBar CodeReaderPOSTerminal1234567

Strona 174 - Equipment

CN2510 User’s Manual Knowing Your Application 3-3Linux Real TTY/Unix Fixed TTY (NT Real COM) CN2510ttyS1 ttyS2 ... ttySNEthernetLinux,

Strona 175

CN2510 User’s Manual Knowing Your Application 3-4Device Control (Device Control) RTU RTU RTUIBM SCO UNIXSUNTCP/IPRxTx1234 5 6 7 8 9 10 11 12 13 14 1

Strona 176

CN2510 User’s Manual Knowing Your Application 3-5UDP Communication (Raw UDP) CN2510TCP/IPSerialFinger PrinterEthernetUDP datagram12345678Serial port

Strona 177

CN2510 User’s Manual Knowing Your Application 3-6Console Management (Reverse Terminal) CN2510TCP/IPTelnetServerRS-232Reverse TelnetmodeRouter Server

Strona 178

CN2510 User’s Manual Knowing Your Application 3-7Terminal Access (Terminal) CN2510TCP/IPRS-232TerminalTerminal TerminalUnixWindows NTRxTx1234 5 6 7

Strona 179

CN2510 User’s Manual Knowing Your Application 3-8Multi-host TTY (Multi-host TTY) CN2510Use hot key to swith sessions between different Unix serversT

Strona 180

CN2510 User’s Manual Knowing Your Application 3-9Dial-in/Out-of-Band Management (Dialin/out) CN2510TCP/IPRouterUNIX Server PC NotebookModemPPPDialou

Strona 181

Configuring ASPP Mode... 4-4 Configuring the Serial Ports...

Strona 182

CN2510 User’s Manual Knowing Your Application 3-10Network Printer (Printer) CN2510TCP/IPRS-232Printer Printer Printer PrinterUnixIBMRxTx123456789101

Strona 183

CN2510 User’s Manual Knowing Your Application 3-11Multiplexor Access (Multiplex) RouterSwitchCode ReaderRS-232RS-232IBM workstationwith multiport bo

Strona 184

44 Chapter 4 Setting Up Windows Real COM/Linux Real TTY/Unix Fixed TTY CN2510 Async Server supports Real COM/TTY drivers for Windows and Linux, al

Strona 185 - Setting Up Routing

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-2 Accessing the Console Utility NOTE In this section, we show how to access CN

Strona 186

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-3Selecting the Application Open Port Menu Æ Mode to configure the NT Real COM

Strona 187 - Configuring RIP

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-45. ASPP mode is selected by default, since it is the only mode associated wi

Strona 188 -

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-5Setting Value Notes Necessity TCP data port 950 – 965 The host uses this

Strona 189 - Internet

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-63. The Line page has pop-up selection lists for Port, Speed, Bits, Stop, Par

Strona 190 - 16 port RS-232 Async Server

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-7You may also save all settings from the MAIN MENU by selecting sAve and then

Strona 191

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-82. Run the Windows Add Hardware Wizard, located in the Control Panel. 3. W

Strona 192

Setting up Hosts ... 9-7 Installing and Compiling Fi

Strona 193 - Administrative Utilities

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-94. Wait patiently while the Wizard searches for servers connected to the net

Strona 194 - Monitor

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-106. Select Add a new hardware device, and then click on Next to continue. 7

Strona 195

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-118. The window that opens next will ask you to select the type of hardware y

Strona 196 - Network

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-1210. Locate and then select the driver file NPSERVER.INF. Click on Open to p

Strona 197

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-1312. The Wizard will start installing the driver, and automatically search t

Strona 198 - PPP-Trace

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-1415. You can select the CN2510 that was located automatically, or select Man

Strona 199 - Diagnostic

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-1517. Click on Finish to complete the installation of the server driver. This

Strona 200 - Upgrade

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-162. Select Include this location in the search, and then click on Next to co

Strona 201 - Console Terminal Upgrade

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-174. The driver for Moxa Port 0 will be installed. 5. After Moxa Port 0 is

Strona 202

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-186. After the installation is complete, you can check Ports (COM & LPT)

Strona 203

Restart ... 13-8 Chapter 14 Administra

Strona 204

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-191. Click on Device Manager Æ Multiport serial adapters, right click on the

Strona 205

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-203. Click on Settings to configure CN2510’s Basic Configuration, Password, a

Strona 206 - Remote RCP Upgrade

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-215. On the Password page, add a password or change the existing password. Ch

Strona 207

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-227. Click on Modify to save all Property Sheet settings and return to the Pr

Strona 208 - Console Terminal Export

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-239. Check the box(es) next to the port(s) you would like to modify, and then

Strona 209

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-24Setting up Windows 2000 Hosts In this section, we explain how to set up a ho

Strona 210

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-254. In the Choose a Hardware Task window, select Add/Troubleshoot a device,

Strona 211 - Console Terminal Import

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-266. In the Find New Hardware window, select No, I want to select the hardwar

Strona 212

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-278. Click on Have Disk to install from the CD, and then click on Next to con

Strona 213

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-2810. Select the correct CN2510 model, and then click on Next to continue. 1

Strona 214 - Default

Async RS-232 Port Cable Wiring... D-3 DB9 and DB25 Connector Pin Assignments .

Strona 215 - Press any key to cancel

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-2912. Although the next window to open states that the software hasn’t passed

Strona 216 - Appendix A Troubleshooting

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-3013. You can select the CN2510 that was located automatically, or select Man

Strona 217 - Console Terminal Problems

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-31Installing Ports 1. The ports will be installed automatically. Click on Fin

Strona 218 - 8 port RS-232 Async Server

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-32Configuring CN2510 in a Windows 2000 Environment After the CN2510 driver is

Strona 219 - Terminal Port Problems

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-333. Click on Settings to configure CN2510’s Basic Configuration, Password, a

Strona 220 - ASPP Port Problems

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-345. On the Password page, add a password or change the existing password. Ch

Strona 221 - RADIUS Problems

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-357. And then click on OK to return to the Access Control page. 8. Click on

Strona 222 - Appendix B RADIUS Server

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-369. Click on Ports Setting to configure the data transmission mode and FIFO

Strona 223 - Setting up CN2510

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-3711. Modify the settings that need to be changed, and then click on OK. Set

Strona 224 - Dialin/out—Dynamic Mode

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-383. The setup program is used for both CN2500 and NPort Server Pro products,

Strona 225 - Dialin/out—PPP/PPPD Mode

11 Chapter 1 Introduction Welcome to Moxa CN2510 Async Server. Models are available with 8 or 16 asynchronous RS-232 ports, and all models come wi

Strona 226 - Setting up UNIX Hosts

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-396. Click on Next to finish installing NPort Pro Manager. 7. After the dri

Strona 227 - Setting up Windows NT Hosts

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-408. Select one of the server’s in the list, or select No, I will define the

Strona 228

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-4110. Select the COM number for CN2510’s port 1. The rest of the ports will b

Strona 229

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-4212. Check the new server settings to make sure they are correct, and then c

Strona 230 - 6. Specify an IP address

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-43Configuring CN2510 in a Windows 95/98/ME/NT Environment After the CN2510 dri

Strona 231

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-443. On the General page, you can see the server’s Serial No., and modify Ser

Strona 232

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-455. The Access Control page allows you to set up access rights for each of t

Strona 233

CN2510 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-467. The Access Control page is used to modify access rights to the server.

Strona 234 - Supported SNMP variables

55 Chapter 5 Setting Up Device Control Device Control applications use standard Linux/Unix Socket programming for Linux/Unix systems, or WinSock p

Strona 235

CN2510 User’s Manual Setting Up Device Control 5-2 Accessing the Console Utility NOTE In this section, we show how to access CN2510’s console utilit

Strona 236

CN2510 User’s Manual Introduction 1-2Product Features Hardware y 1 LAN port (auto-detecting 10/100 Mbps Ethernet) y Surge protection for each seri

Strona 237 - Cable Wiring

CN2510 User’s Manual Setting Up Device Control 5-3Selecting the Application Open Port Menu Æ Mode to configure the Device Control application. 1. F

Strona 238

CN2510 User’s Manual Setting Up Device Control 5-45. ASPP mode is selected by default. CN2510-8 CN2510-8_5631 V2.0

Strona 239

CN2510 User’s Manual Setting Up Device Control 5-52. Use the arrow keys to highlight ASPP, and then press Enter. CN2510-8 C

Strona 240 - Appendix E LCM Display

CN2510 User’s Manual Setting Up Device Control 5-6Setting Value Notes Necessity TCP data port 950 – 965The host uses this value to determine whi

Strona 241

CN2510 User’s Manual Setting Up Device Control 5-72. Use the arrow keys to highlight RAW, and then press Enter. CN2510-8 CN

Strona 242

CN2510 User’s Manual Setting Up Device Control 5-8Configuring the Serial Ports Open Port Menu Æ Line to configure serial port settings. 1. From the

Strona 243 -  Product Return Procedure

CN2510 User’s Manual Setting Up Device Control 5-9Save When exiting the SERVER MENU, you will be prompted to save settings. Press Y to save. CN2510-

Strona 244 - MOXA Internet Services

CN2510 User’s Manual Setting Up Device Control 5-10ASPP Library Introduction The CN2510 Documentation and Software CD contains example programs that

Strona 245 - MOXA CN2510 Series

CN2510 User’s Manual Setting Up Device Control 5-11ASPP Examples for Windows 1. Program testing environment: RS-232CN2510EthernetTerminalWindows PC

Strona 246 - Product Return Procedure

66 Chapter 6 Setting Up Raw UDP UDP is a non connection-oriented data transmission method. By circumventing TCP’s handshaking process, UDP gains t

Komentarze do niniejszej Instrukcji

Brak uwag