Moxa Technologies V460 Series Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Podręczniki do oprogramowania Moxa Technologies V460 Series. Moxa Technologies V460 Series User`s manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 35
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
V460 Series
WinXP Embedded Users Manual
Fourth Edition, May 2009
www.moxa.com/product
© 2009 Moxa Inc. All rights reserved.
Reproduction without permission is prohibited.
Przeglądanie stron 0
1 2 3 4 5 6 ... 34 35

Podsumowanie treści

Strona 1 - WinXP Embedded User’s Manual

V460 Series WinXP Embedded User’s Manual Fourth Edition, May 2009 www.moxa.com/product © 2009 Moxa Inc. All rights reserved. Reproduction without pe

Strona 2

V460 Series WinXP Embedded User’s Manual Introduction ATTENTION You must remove the power source first before inserting or removing the CompactFlash

Strona 3 - Table of Contents

22 Chapter 2 Software Configuration In this chapter, we explain how to operate a V460-XPE computer directly or from a PC. Instructions are given on

Strona 4 - Introduction

V460 Series WinXP Embedded User’s Manual Getting Started Starting Your V460-XPE Computer Connect the CRT monitor or LCD monitor to the target compute

Strona 5 - Software Specifications

V460 Series WinXP Embedded User’s Manual Getting Started Operating Your V460-XPE Computer with a Telnet Client Use a crossover Ethernet cable to con

Strona 6

V460 Series WinXP Embedded User’s Manual Getting Started 2-4

Strona 7

V460 Series WinXP Embedded User’s Manual Getting Started Adjusting the System Time y Setting the System Time Manually: Use the date/time command lin

Strona 8

V460 Series WinXP Embedded User’s Manual Getting Started Starting and Stopping Services Select Start Æ Control Panel Æ Administrative Tools and doubl

Strona 9

V460 Series WinXP Embedded User’s Manual Getting Started Enhanced Write Filter The “Enhanced Write Filter” protects the contents of a volume on the

Strona 10

V460 Series WinXP Embedded User’s Manual Getting Started Using the Battery Backed-up SRAM The V460 embedded computer has a 256 KB SRAM backed up by a

Strona 11 - Software Configuration

V460 Series WinXP Embedded User’s Manual Getting Started 2-9Reading Data from SRAM // Persisted_SRAM_Read.cpp : Defines the entry point for the cons

Strona 12

V460 Series WinXP Embedded User’s Manual The Moxa software described in this manual is furnished under a license agreement and may be used only in ac

Strona 13

33 Chapter 3 Management Tools The V460-XPE ready-to-run embedded computers are shipped with the Windows XP Embedded operating system already instal

Strona 14

V460 Series WinXP Embedded User’s Manual Management Tool Computer Management [Control Panel] Æ [Administrative tools] Æ Computer Management. You can

Strona 15 - Adjusting the System Time

V460 Series WinXP Embedded User’s Manual Management Tool Event Viewer [Control Panel] Æ [Administrative tools] Æ Event Viewer. Every V460-XPE event,

Strona 16 - Serial Ports

V460 Series WinXP Embedded User’s Manual Management Tool A default web page is located in the directory c:\Inetpub. Use this default page to test yo

Strona 17 - Enhanced Write Filter

V460 Series WinXP Embedded User’s Manual Management Tool 3-5

Strona 18 - Writing Data to SRAM

V460 Series WinXP Embedded User’s Manual Management Tool 3-6

Strona 19 - Reading Data from SRAM

V460 Series WinXP Embedded User’s Manual Management Tool 3. When you complete the steps, the virtual directory WEB will appear under Default WEB S

Strona 20 - Management Tools

V460 Series WinXP Embedded User’s Manual Management Tool 3-8

Strona 21 - Component Services

V460 Series WinXP Embedded User’s Manual Management Tool ODBC Data Source Administrator [Control Panel] Æ [Administrative tools] Æ ODBC. This databa

Strona 22 - Event Viewer

V460 Series WinXP Embedded User’s Manual Management Tool Services [Control Panel] Æ [Administrative tools] Æ Services You can use this utility to s

Strona 23

Table of Contents Chapter 1 Introduction ...1-1 Overv

Strona 24

44 Chapter 4 System Recovery The V460-XPE ready-to-run embedded computers use a Windows XP Embedded platform. Although it happens rarely, you may f

Strona 25

V460 WinXP Embedded User’s Manual System Recovery Recovery environment The recovery environment includes the V460-XPE embedded computer and a bootab

Strona 26

V460 WinXP Embedded User’s Manual System Recovery Step 2: Create a Windows XP Embedded Bootable USB Disk. a. Copy the V460XPE.zip and USBBoot.zip

Strona 27

V460 WinXP Embedded User’s Manual System Recovery Step 4: Copy Windows XPE system files to DOM or CompactFlash Disk. a. If the BIOS setup is co

Strona 28 - Performance Monitor

V460 WinXP Embedded User’s Manual System Recovery Step 5: Setup BIOS back to Boot from DOM or CompactFlash Disk. a. Power on and press DEL to ent

Strona 29 - Services

V460 WinXP Embedded User’s Manual System Recovery 4-6

Strona 30 - System Recovery

11 Chapter 1 Introduction Thank you for purchasing the Moxa’s V460 series of x86 ready-to-run embedded computers. This manual introduces the softwa

Strona 31 - Recovery procedures

V460 Series WinXP Embedded User’s Manual Introduction Overview The x86 ready-to-run embedded computers in the V460 series are designed around the AMD

Strona 32

V460 Series WinXP Embedded User’s Manual Introduction Windows XP Embedded is based on the same binary files as Windows XP Professional; Windows XP Em

Strona 33

V460 Series WinXP Embedded User’s Manual Introduction y RPC—Facilitates local remote procedure calls (RPCs) using the ncalrpc and ncacn_np protocol

Strona 34

V460 Series WinXP Embedded User’s Manual Introduction y Time Service Core—Synchronizes a workstation's clock with other computers using the Net

Strona 35

V460 Series WinXP Embedded User’s Manual Introduction Inserting a USB Mass Storage Device into the Computer Inserting a USB mass storage device will

Komentarze do niniejszej Instrukcji

Brak uwag